This guide explains how to feed MeshCore data into LincsMesh CoreScope using MQTT and configure regions on a participating repeater.

If you are setting up a feeder, follow sections 1–4. If you also operate a repeater, follow section 5 to configure regional traffic.

1. Sign in to LincsMesh

  1. Open LincsMesh.
  2. Sign in to your account, or create an account if you do not already have one.
  3. Open My Account.

2. Register your publishing device

Do this before configuring MQTT. Your publishing device must be linked to your LincsMesh account.

  1. In My Account, find the companion/node details section.
  2. Add the MeshCore device you intend to use as your feeder.
  3. Enter the device’s full public key exactly as shown by your device.
  4. Set it as your static companion.
  5. Save your profile and check that the companion is listed.

Use the public key, not a private key. Copy the entire key without extra spaces or missing characters.

For an OpenHop repeater or Gessaman observer: register the publishing device’s public key as your companion, even if the device is already claimed as your repeater. Set this as your static companion.

The public key in your profile must match the device publishing to MQTT. A missing or mismatched key can cause publishing to be rejected even when your MQTT login details are correct.

3. Retrieve your MQTT details

While signed in, open the MQTT / feeder section in My Account. Follow the instructions there to view, request or generate your MQTT credentials.

You will need your LincsMesh MQTT username and password. Your MQTT password is not necessarily the same as your website login password.

Keep these credentials private.

4. Configure your MQTT feeder

Choose the instructions for your setup below.

How do I set up the MQTT feed in Home Assistant?

Before you begin

  • Make sure your MeshCore companion is connected to the MeshCore integration in Home Assistant.
  • Register its full public key as your static companion on LincsMesh.
  • Have your LincsMesh MQTT username and password ready.

Open the MQTT settings

In Home Assistant, go to Settings → Devices & services → MeshCore, then open the integration’s configuration and find MQTT Broker Settings.

Configure the broker

SettingValue
EnabledTick
Servermqtt.lincsmesh.co.uk
Port443
Transportwebsockets
Use TLSTick
Verify TLS CertificateTick
Keepalive (seconds)60
UsernameYour LincsMesh MQTT username, e.g. lincsmesh_xxxx
PasswordYour LincsMesh MQTT password
Use MeshCore Auth TokenLeave unticked
Token AudienceLeave blank
Owner Public Key (JWT owner claim)Leave blank
Owner Email (JWT email claim)Leave blank
Payload ModePacket (LetsMesh-compatible)
Auth Token TTL (seconds)Leave at 3600
Status Topicmeshcore/{IATA}/{PUBLIC_KEY}/status
Packets Topicmeshcore/{IATA}/{PUBLIC_KEY}/packets
Broker IATA CodeYour local airport identifier, e.g. HUY, EMA, DSA, NWI or LBA

Keep {IATA} and {PUBLIC_KEY} exactly as shown in the topic fields. The integration fills these placeholders automatically.

The JWT owner fields can remain blank when using your LincsMesh MQTT username and password. Your companion’s public key must still be registered in your LincsMesh profile.

Save the settings

Click Submit and complete any remaining configuration prompts.

Check the feed

Visit LincsMesh CoreScope observers and check that your companion is reporting successfully.

How do I set up the MQTT feed for an OpenHop repeater?

Thank you to BlackSpider for writing these instructions.

Before you begin

  • Obtain your MQTT username and password from LincsMesh.
  • Copy your OpenHop repeater’s full public key.
  • Register this key as your companion on LincsMesh, even if the device is already claimed as your repeater.
  • Set this as your static companion.

Configure the observer

Log in to the OpenHop web interface and go to System → Observer → Observer config → Edit settings.

SettingValue
IATA codeYour local airport identifier, e.g. HUY, EMA, DSA, NWI or LBA
Status interval300
Owner companion keyYour OpenHop repeater’s full public key

Configure the MQTT broker

Under Broker settings, enter:

SettingValue
NameLincsmesh
FormatMeshcoretomqtt
EnabledTick
TransportWebsockets
Hostmqtt.lincsmesh.co.uk
UsernameYour LincsMesh MQTT username, e.g. lincsmesh_xxxx
Port443
PasswordYour LincsMesh MQTT password
TLS enabledTick

Save and restart

  1. Click Done.
  2. Click Save Settings at the top of the page.
  3. Click Validate and Restart.

Check the feed

Visit LincsMesh CoreScope observers and check that your repeater is reporting successfully.

How do I set up the MQTT feed using Gessaman observer CLI commands?

Before you begin

  • Your device must be running Gessaman’s MQTT Observer firmware.
  • Register the observer’s full public key as your static companion in My Account on LincsMesh.
  • Have your LincsMesh MQTT username and password ready.
  • Make sure the observer’s radio settings match your local mesh.

Custom broker commands can vary between firmware versions. Check the commands supported by your installed build before applying the configuration.

Open the console

Open your observer’s web configuration interface and select CLI, or connect over USB using the console at Gessaman’s observer flasher.

Check your existing configuration

Run:

get mqtt.presets
get mqtt.status

Choose a broker slot you are happy to configure. The example below uses slot 1 and replaces its existing broker settings.

If you use another supported slot, replace mqtt1 with that slot throughout.

Configure Wi-Fi

If your observer is not already connected to Wi-Fi, enter:

set wifi.ssid YOUR_WIFI_NAME
set wifi.pwd YOUR_WIFI_PASSWORD

Replace the placeholders with your own Wi-Fi details.

Configure the LincsMesh broker

The following example uses HUY as the local airport code. Change this if another airport identifier is more appropriate.

Replace YOUR_MQTT_USERNAME and YOUR_MQTT_PASSWORD with the credentials supplied in My Account.

For builds supporting a complete server URL, enter these commands one at a time:

set mqtt1.preset custom
set mqtt1.server wss://mqtt.lincsmesh.co.uk:443
set mqtt1.username YOUR_MQTT_USERNAME
set mqtt1.password YOUR_MQTT_PASSWORD
set mqtt.iata HUY
set mqtt.enabled on
set mqtt.packets on
set mqtt.status on

The wss:// address specifies secure WebSockets.

If your firmware rejects a command or provides separate transport, TLS or port settings, use its version-specific configuration controls with:

SettingValue
Servermqtt.lincsmesh.co.uk
Port443
TransportWebSockets
TLSEnabled
Verify TLS certificateEnabled
AuthenticationLincsMesh MQTT username and password

If a WebSocket path is required, use the value supplied by LincsMesh.

Restart and check

Once all settings have been accepted, restart the observer:

reboot

After it reconnects, check:

get wifi.status
get mqtt.status
get mqtt1.diag
get mqtt.iata

Diagnostic commands may differ between firmware versions.

Confirm that Wi-Fi and MQTT are connected, then visit LincsMesh CoreScope observers and check for your device’s activity.

Your observer’s full public key must match the static companion registered in your LincsMesh profile.

Keep your Wi-Fi and MQTT passwords private when sharing console output or screenshots.

What are the generic MQTT settings?

Use these settings if you are configuring another type of feeder. Your feeder must support MQTT over secure WebSockets.

Before you begin

  • Register your publishing device’s full public key as your static companion in My Account on LincsMesh.
  • Obtain your LincsMesh MQTT username and password.

Connection settings

SettingValue
Broker/servermqtt.lincsmesh.co.uk
Port443
TransportWebSockets
TLS / SSLEnabled
Verify TLS certificateEnabled
UsernameYour LincsMesh MQTT username, e.g. lincsmesh_xxxx
PasswordYour LincsMesh MQTT password
Keepalive60 seconds
IATA codeYour local airport identifier, e.g. HUY, EMA, DSA, NWI or LBA
Payload formatMeshCore packet format compatible with Meshcoretomqtt / LetsMesh

If your feeder asks for a WebSocket path, use the value supplied by LincsMesh.

MQTT topics

Message typeTopic template
Statusmeshcore/{IATA}/{PUBLIC_KEY}/status
Packetsmeshcore/{IATA}/{PUBLIC_KEY}/packets

Replace {IATA} with your chosen airport code and {PUBLIC_KEY} with your publishing device’s full public key, unless your feeder fills these placeholders automatically.

The public key must match the static companion registered in your LincsMesh profile.

Save and check

  1. Enable packet and status publishing where supported.
  2. Save the settings and restart the feeder if required.
  3. Check the feeder’s status or logs to confirm it connects successfully.
  4. Visit LincsMesh CoreScope observers and check for your device’s activity.

Connecting to the broker is only part of the setup. Your feeder must also publish messages using a compatible payload format and the correct topics.

5. Configure regions on your repeater

This section applies to repeaters participating in the Lincolnshire MeshCore Network.

Regions help organise traffic geographically, allowing messages intended for Lincolnshire to travel through participating repeaters while reducing unnecessary propagation into other areas.

MQTT feeding and repeater regions are separate settings. Configuring one does not automatically configure the other.

How do I configure my repeater’s regions?

Connect to your repeater

Connect to your MeshCore repeater using a compatible CLI interface.

Add the regions

Enter the following commands one at a time, pressing Enter after each command. Ensure you receive an ok response before continuing.

region put lincolnshire
region default lincolnshire
region put yorkshire
region put eng-ne
region put northwest
region save

What each command does

CommandDescription
region put lincolnshireAdds the Lincolnshire region
region default lincolnshireSets Lincolnshire as the default region
region put yorkshireAdds the Yorkshire region
region put eng-neAdds the North East England region
region put northwestAdds the North West England region
region saveSaves the region configuration

Verify your configuration

Once the regions have been saved, check your configuration using:

region list allowed

Check that the expected regions appear in the allowed list.

Update your repeater information

Update your repeater information on LincsMesh to confirm that your repeater supports the Lincolnshire scope.

This helps others identify repeaters that support Lincolnshire regional traffic.

Configuration notes

  • Enter region names exactly as shown, using lowercase letters.
  • Run region save after making changes.
  • Only configure regions appropriate to your repeater and its intended network participation.
  • Adding these regions does not itself configure a policy to block unscoped traffic. Existing forwarding and flood settings still apply.

6. Check that your setup is working

MQTT feeder

  1. Check your feeder’s connection status or logs to confirm it has connected to the MQTT broker.
  2. Allow time for it to publish status messages and receive MeshCore traffic.
  3. Open LincsMesh CoreScope observers.
  4. Find your device and check its latest activity.

Repeater regions

  1. Run region list allowed.
  2. Confirm that the expected regions are listed.
  3. Make sure you have run region save.
  4. Update your repeater information to show that it supports the Lincolnshire scope.

Troubleshooting

ProblemWhat to check
MQTT authentication failsRe-check your MQTT username and password in My Account. Your website password may be different.
Publishing is rejected despite correct credentialsConfirm the publishing device is registered as your static companion and its full public key matches your profile.
Feeder cannot connectCheck the server address, port 443, WebSockets transport and TLS settings.
Feeder connects, but no data appearsCheck the topic settings, local airport IATA code and packet publishing settings. Allow time for radio traffic to be received.
Only some data appearsCheck that both packet and status publishing are configured where supported.
You cannot find your MQTT detailsOpen My Account on LincsMesh and find the MQTT / feeder section. Follow the instructions shown there.
A Gessaman CLI command is rejectedCheck the commands supported by your installed firmware. Use its web configuration interface if the CLI syntax differs.
A Gessaman broker slot stops feeding another serviceCheck which slot was changed. Configuring a slot replaces its previous broker settings.
Expected regions are missingCheck the spelling of each region, add any missing entries and run region save.
A region command is not recognisedCheck your repeater firmware and consult the CLI documentation for that version.

If you still need help, contact the LincsMesh site administrator. Include your device or feeder type, software version and any error message.

Never send your MQTT password, Wi-Fi password, token or private key in a public post or screenshot.

Useful links